Welcome to Foshan Powtech Technology Company Limited!https://www.powtechina.com
Specification for the use and commissioning of electromagnetic iron remover
published date: 2019/5/31

high intensity magnetic separator

PTMS magnetic separation

what is magnetic separation in science?

1. Before the electromagnetic separator is turned on, first check whether the indicated oil level is at the upper limit of the oil mark. And each line switch power transmission, and start the excitation circuit, check the fan airflow outward, the flow meter indication is correct. Otherwise, the fan and special pump electrical wiring should be adjusted.
2. Always observe whether the readings of the voltmeter and ammeter are normal and must not exceed their rated values.
3. If the iron removal effect is not good, adjust the lifting height or the front and rear distance of the electromagnetic iron remover and the head roller
4. Check the electrical insulation performance of the coil and the motor.
5. Before the operation of the electromagnetic iron remover, use the megohmmeter. Measure the insulation resistance of the winding to the magnet housing. The value should be less than 10MΩ. Check whether the wiring of the excitation winding is correct and reliable.
The company has accumulated many years of experience in the production of iron removal equipment, integrating design, manufacture, sales and maintenance, production and maintenance of various types of iron remover, electromagnetic iron remover, electromagnetic iron remover, lifting electromagnet, magnetic separator and other equipment. Widely used in electric power, metallurgy, coal, mining, building materials, chemicals, paper, sugar, ceramics and other industries.

Share to:

Powtech Machinery Company produce magnetic separator, Industrial Magnetic Separators, Industrial magnetic separation equipments,Magnetic Equipment,Permanent Suspension Magnet,Vibrating Equipment