What should I do if the electromagnetic iron remover fails?
published date: 2019/9/5
eriz magnetic separator
PTMS magnetic separation
what is magnetic separation method?
The electromagnetic separator has failed, mainly considering the following factors
1. Check if the contact performance of the lower electromagnetic coil is good and reliable grounding.
2. Whether the soft connection between the electromagnetic iron remover and the control cabinet is intact.
3. Whether the voltage of the electromagnetic iron remover control cabinet still reaches 380V or 220V standard.
4. Whether the power cord is damaged or not, and a short circuit condition occurs.