electromagnetic separator
PTMS MAGNETIC SEPARATOR
what is magnetic separation in science?
1. The installation angle of the pipeline type iron remover is preferably 55°-60°. The direction of both sides of the motor axis should not be inclined and kept horizontal. The discharge port should not be tightly connected with the tapping pipe, and the rectangular iron bucket or slotted iron should be connected. It is advisable to connect the iron to the trough, and the distance between the taphole and the iron bucket is 60mm, so that if necessary, the obstructions, such as iron wire and material block, which may appear in the taphole are manually removed.
2. Pipe type iron remover The electronic control system of this equipment can be directly connected to the power supply, and the equipment can work alone; it can also be controlled by the powder conveying system. The opening and closing of the system determines whether the equipment works or not. Pads or asbestos ropes must be placed between the inlet and outlet flange joints to ensure the sealing performance of the joints to prevent dust from eroding the environment.
3. After the first power-on after power-on, you must observe whether the equipment is running in the right direction:
A. Observe the steering of the geared motor, and the direction of rotation is consistent according to the direction of the arrow on the chain;
B. Open the side observation port and place a ferromagnetic material (nut, etc.) with a particle size of less than 22 mm on the surface of the adsorption baffle. The movement of the object to the lower tap hole is correct. If the direction of motion is not correct, shut down immediately, change the direction of motor rotation and try again.
4. Before using the pipeline type iron remover, according to the mixing amount of ferromagnetic debris in the powder, adjust the start and stop time of the motor and adjust the button of the time relay in the electric control box to change the two times. The value can be directly Look at the button. The reference selection time is: exercise time 10 seconds; intermittent time 3 to 10 minutes.
5. Under no circumstances should an excessively large iron block (≥0.1kg, length ≥80mm) be allowed to enter the pipeline type iron remover machine, so as to avoid the magnet group failure or affect the iron removal effect.
6. Pipeline type iron remover must be filled with N68 (old brand 40#) mechanical lubricating oil from the oil filling port before use. Refueling to the middle position of the oil level observation window, after use, it is found that the oil level is insufficient, it can be added to the center position of the oil level observation window, and the oil replacement period of the pipeline type iron remover is one year.