Welcome to Foshan Powtech Technology Company Limited!https://www.powtechina.com
The reason of low concentrate grade can be solved by adjusting PTMS magnetic separator
published date: 2021/7/17

wet separator

Reasons and solutions for low concentrate grade, in order to verify the effect of field high intensity magnetic separation PTMS magnetic separator and gravity separation operation, the field high intensity magnetic separation feed ore and gravity separation feed ore for verification test.

PTMS magnetic separator

The verification test results show that: the field high intensity magnetic separation feed ore and gravity separation feed ore particle size is coarser, and the coarse grade is significantly lower (especially for the gravity separation), this part of the coarse grade is easy to cause high intensity magnetic separation medium box clogging, worsening the effect of high intensity magnetic separation, and difficult to remove in the gravity separation operation, thus leading to low grade of gravity separation concentrate iron. Therefore, it is advisable to screen the + 0. 3 mm particle size before the high magnetic PTMS magnetic separator.

what is magnetic bead separation?

At the same time, combined with the high intensity magnetic separation equipment exposed during the process inspection of the volume of excessive per hour,PTMS appropriately improve the concentration of high intensity magnetic separation PTMS magnetic separator to improve the separation effect of high intensity magnetic separation.
Contact: DELLA
Mob: +86-13929907491
sales@powtechina.com

PTMS MAGNETIC SEPARATOR 20210717659

Share to:

Powtech Machinery Company produce magnetic separator, Industrial Magnetic Separators, Industrial magnetic separation equipments,Magnetic Equipment,Permanent Suspension Magnet,Vibrating Equipment