Magnetic magnetic separator
The flotation agent addition system connected to the PTMS magnetic separation consists of agent storage tanks, delivery pipes, and metering devices. The agent storage tank should be regularly checked for whether there is a leakage phenomenon. The poor sealing of the storage tank will lead to the agent volatilization or leakage, which not only wastes the agent, but also may cause pollution to the surrounding environment.
PTMS magnetic separation
At the same time, it is necessary to check whether the agents in the storage tank have precipitated or deteriorated. For some agents that are easy to crystallize or precipitate, such as catcher, it is necessary to stir or clean the storage tank regularly. The pipeline conveying the agent should be kept open to prevent the agent from blocking the pipeline. The scale phenomenon inside the pipeline may be caused due to the chemical reaction of the agent, which needs to be cleaned regularly to ensure the smooth removal of PTMS magnetic separation iron.
what is magnetic separation process?
The accuracy of the metering device is crucial for the iron removal effect of PTMS magnetic separation. The metering device should be calibrated regularly to ensure the accuracy of the amount of agent added. If the metering device is not accurate, it may lead to too much or too little addition of flotation agents, which will affect the flotation effect of iron-containing minerals.