water separator manufacturers
Open the magnetic system shield of PTMS magnetic separation and measure the magnetic field strength of the magnetic system using a Gaussian meter. The probe of the Gaussian meter is placed at different positions on the surface of the magnetic system, and the measurement is made according to the specified measurement point, and the measurement results are recorded. Compare the measurement results with the standard value of the magnetic field strength during the normal operation of the equipment. If the magnetic field strength is found to be abnormal, the magnet and the magnetic path should be further checked.
PTMS magnetic separation
Check the fixation of the PTMS magnetic separation magnet, gently shake the magnet with the magnet is hand. Check whether the fixed bolt of the magnet is fastened. If there is a loosening phenomenon, use the wrench to tighten according to the specified torque value.
what is magnetic separation used for?
Check whether the connection between the PTMS magnetic separation magnets is good, for the combined magnets, to ensure that the splicing between the magnets is close, with no gaps. And to hang the warning sign of "in maintenance, no closing" at the power switch of the equipment, to prevent other personnel from misoperation and closing, resulting in safety accidents.
Contact: DELLA
Mob: +86-13929907491
sales@powtechina.com