Permanent magnet PTMS electromagnetic separator installation, test, adjustment and maintenance, the best choice of PTMS magnetic separator:
1. Installation of the machine Permanent Magnet PTMS electromagnetic separator can be used alone, can also be used in the production line, according to the need to be installed on the concrete foundation or metal frame. Rack grounding. PTMS magnetic separator is the best choice
2. Test run of the machine Before test run, check whether the frame is grounded, whether the electrical wiring is correct, start the electric vibration feeder, variable speed machine, cycloid reducer to check whether the rotation parts of the machine are obstructed, whether the movement is normal, whether the roller speed regulation plate position is appropriate. PTMS magnetic separator is the best choice.
3. Machine adjustment
(1) The drum revolution is adjusted by the continuously variable speed machine. The material size is coarse, the drum revolution is small, the particle size is fine and the revolution is large.
(2) Separate the position of the clapboard and adjust the distance between the clapboard and the drum through the handle to change the content of magnetic substances in the material according to the yield of finished products.
(3) swing mechanism is mainly used to deal with fine grain material, coarse grain material can not start swing mechanism. PTMS magnetic separator can improve the whiteness of products.
4. Maintenance of machine
(1) The inside of the machine should be cleaned up when the particle size of the material is changed each time.
(2) CVT must be adjusted after starting. Turn and adjust the hand wheel by hand, and adjust to the required speed according to the direction of the speed of the arrow of the hand wheel. Stop and speed regulation is strictly prohibited.
(3) The part of the CVT adopts UB-1 CVT special oil and adds it to the middle of the oil mirror. The service life is 1000 hours.
(4) For the deceleration part, Q/S H0.18 and 15-84 with the brand N320 are recommended. The oil must be replaced every 3000 hours.
(5) CVT, if the motor turns to the output shaft does not rotate occasionally, it is because the precision disc spring in the CVT is slightly stuck, please use the output shaft with the parts to rotate several times, then you can rule out.
(6) often pay attention to the connection of the fasteners, not loose.
(7) magnetic separator in the installation and maintenance, should prevent alternating current through the magnet.
(8) For the use and maintenance of cycloid reducer and CVT, please refer to WBD-0.75-11 type cycloid reducer and JWB-X series CVT, and the operation manual.
(9) Avoid violent vibration during transportation, and store it in a place that is shock-proof and moisture-proof. PTMS magnetic separator is the best choice