Strong magnetic separator has no magnetic method
published date: 2019/5/16
Magnetic separator equipment
PTMS magnetic separation
what is magnetic separation method for concentration of ore?
Strong magnetic separators are widely used. Due to their common use, the internal parts need to be replaced and repaired frequently. The excitation coils are also very easy to burn out. Some parts will appear without damage. Some faults, such as non-magnetic faults. Qingdao shot blasting machine surface introduces the magnetic magnetic separator without magnetic force exclusion method:
When the power is applied to the strong magnetic separator, the workpiece cannot be held. Due to the relay interlock of the relay, the grinding wheel motor cannot be started normally. It can be judged that the strong magnetic separator has no magnetic force. Fault. At this time, we need to open the power distribution box of the CNC machine. The hook type shot blasting machine uses the test pencil to perform power verification on both ends of the fuse, and then use the 500 volt measurement file of the universal measuring meter to measure whether the voltage is 380 volts. Then disconnect the main power switch and check the AC contactor for mechanical jamming. US Red Maple then remove the coil and wire of the contactor. Use the multimeter's resistance file to measure the resistance at both ends of the safety. If the needle indicates normal The coil is normal.
After we cut off the main switch, we use the multimeter's resistance file to measure the four rectifier diodes separately, and observe whether there is any problem with the diode. If the diode is found to be broken down, then replace the new diode and solder it firmly. After testing the strong magnetic removal Iron can be used normally.